Mounting - wall
GH wall brackets
Use
The GH wall brackets are used to instal all types of rail between
vertical surfaces. The bracket can be used, for example, in
connection with installing room covering rail systems in rooms where the ceiling is inaccessible or slanting and where it is not possible to install reinforcements with the GH stabiliser bracket. The GH wall bracket can be installed on all types of wall - both brick and concrete, lightweight concrete, wood and plasterboard. However, the GH wall bracket must be combined with a GH plasterboard bracket on plasterboard walls whithout wall reinforcement.
Installation
The GH wall bracket must be secured to the wall with two fixings.
Note
The GH wall bracket can be used either for side-mounted rails or for end-mounted rails.

GH wall bracket for side-mounted rails
Use
The GH wall brackets for side mounted rails are used in connection with installation of a room covering system, where long parallel rails are to be fixed along a wall.
Installation
The GH wall bracket must be secured to the wall with two fixings.
Note
The GH wall bracket can be used either for side-mounted or for end-mounted rails.
GH plasterboard bracket
Use
The GH plasterboard bracket is used as an adapter for the GH wall bracket in connection with installations on plasterboard walls or other types of light wall. A GH plaster board bracket provides the necessary high stability and strength to install rail systems on plasterboard walls. However, it is a requirement that these are double plasterboard walls at least 24 mm thick.
Installation surface: (WxH) 303x303 mm.
Installation
The GH plasterboard bracket can be secured direct to the plasterboard wall with 6 pcs HILTI HTB-S M6x60. The GH wall bracket must then be secured to the two threaded rods on the GH plasterboard bracket with 10 mm lock nuts.
Exception
Must not be used in systems with a maximum load over 250 kg.
|